cve
cve

CVE-2024-4999

A vulnerability in the web-based management interface of multiple Ligowave devices could allow an authenticated remote attacker to execute arbitrary commands with elevated privileges.This issue affects UNITY: through 6.95-2; PRO: through 6.95-1.Rt3883; MIMO: through 6.95-1.Rt2880; APC Propeller:...

7.6AI Score

0.0004EPSS

2024-05-16 01:15 PM
24
cve
cve

CVE-2021-44228

Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message....

10CVSS

9.8AI Score

0.976EPSS

2021-12-10 10:15 AM
3635
In Wild
399
cve
cve

CVE-2021-22790

A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP and BMEH, all versions), Modicon M340 CPU (part...

6.5CVSS

6.4AI Score

0.001EPSS

2021-09-02 05:15 PM
24
cve
cve

CVE-2021-22791

A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP and BMEH, all versions), Modicon M340 CPU (part...

6.5CVSS

6.4AI Score

0.001EPSS

2021-09-02 05:15 PM
20
cve
cve

CVE-2021-22792

A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP and BMEH, all versions), Modicon M340 CPU...

7.5CVSS

7.4AI Score

0.001EPSS

2021-09-02 05:15 PM
31
cve
cve

CVE-2021-22789

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers...

6.5CVSS

6.4AI Score

0.001EPSS

2021-09-02 05:15 PM
19
cve
cve

CVE-2021-22778

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all...

7.1CVSS

6.7AI Score

0.0005EPSS

2021-07-14 03:15 PM
31
3
cve
cve

CVE-2021-22780

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all...

7.1CVSS

6.8AI Score

0.0005EPSS

2021-07-14 03:15 PM
23
5
cve
cve

CVE-2021-22781

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all...

5.5CVSS

5.5AI Score

0.0005EPSS

2021-07-14 03:15 PM
27
2
cve
cve

CVE-2021-22782

Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all...

5.5CVSS

5.3AI Score

0.0005EPSS

2021-07-14 03:15 PM
34
3
cve
cve

CVE-2021-22779

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack.....

9.1CVSS

9AI Score

0.002EPSS

2021-07-14 03:15 PM
34
3
cve
cve

CVE-2020-7560

A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™...

8.6CVSS

8.7AI Score

0.001EPSS

2020-12-11 01:15 AM
40
1
cve
cve

CVE-2020-7559

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a...

7.5CVSS

7.4AI Score

0.001EPSS

2020-11-19 10:15 PM
33
cve
cve

CVE-2020-7538

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted...

7.5CVSS

7.5AI Score

0.001EPSS

2020-11-19 10:15 PM
28
cve
cve

CVE-2020-28211

A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a...

7.8CVSS

7.7AI Score

0.0005EPSS

2020-11-19 10:15 PM
22
cve
cve

CVE-2020-28213

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over...

8.8CVSS

8.8AI Score

0.001EPSS

2020-11-19 10:15 PM
25
cve
cve

CVE-2020-28212

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over...

9.8CVSS

9.5AI Score

0.004EPSS

2020-11-19 10:15 PM
21
2
cve
cve

CVE-2020-7475

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580.....

9.8CVSS

9.2AI Score

0.002EPSS

2020-03-23 07:15 PM
44
cve
cve

CVE-2019-6855

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between...

7.3CVSS

7.2AI Score

0.001EPSS

2020-01-06 11:15 PM
142
6
cve
cve

CVE-2016-8354

An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity...

7CVSS

6.9AI Score

0.001EPSS

2017-02-13 09:59 PM
27
cve
cve

CVE-2014-9200

Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM.....

8.2AI Score

0.182EPSS

2015-02-01 03:59 PM
35
cve
cve

CVE-2013-0662

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application...

7.6AI Score

0.115EPSS

2014-04-01 06:17 AM
76
cve
cve

CVE-2011-3330

Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and...

8AI Score

0.006EPSS

2011-11-04 09:55 PM
38